CLASS B23G Class B Steam Sterilizer · 18L/23L
Compare the configuration, not just the model name.
RUNDA manufactures the 23G steam autoclave range for clinic and distributor instrument-processing projects. Standard, Color Screen and Pro documents describe different interface and workflow configurations, with 18 L / 23 L chambers and cycle-printing features.
- 18 L / 23 L
- Standard / Color Screen / Pro
- Cycle-record printing
Model: 23GBrand: RUNDA
PRODUCT INFORMATION
Technical Parameters
The 23G pairs 18 L / 23 L chamber choices with Standard, Color Screen and Pro configurations. Compare the documented cabinet dimensions and operating features before choosing a version.
23G Performance Highlights



Configuration & Specifications
| Parameter | Standard | Color Screen | Pro |
|---|---|---|---|
| Capacity options | 18 L / 23 L | ||
| Chamber diameter × depth | 18 L: Ø245 × 355 mm; 23 L: Ø245 × 465 mm | ||
| External dimensions | 652 × 420 × 495 mm | 660 × 455 × 445 mm | 652 × 420 × 495 mm |
| Water storage tank | 3.5 L | ||
| Program temperatures | 121 °C / 134 °C | ||
| Operating environment | +5 to +40 °C; relative humidity ≤85% | ||
| Power supply | 220 V AC / 50 Hz | — | |
| Cycle records | Built-in thermal printer described | Thermal printer and on-screen print history described | Built-in thermal printer described |
| Interface | — | Vertical full-color LCD touchscreen | — |
| Drying settings | — | Fast / Standard / Accelerated | — |
| Air removal and drying | — | Triple pre-vacuum and vacuum drying described for Pro | |
— indicates a specification not listed for that version. Request the configuration sheet before ordering.
Sterilization Programs
Hold time and drying time are separate cycle phases. Select the program for the intended load and the supplied configuration.
Standard programs
Swipe the table sideways to view all columns. The first column stays visible.
| Program | Temperature | Hold time | Drying time |
|---|---|---|---|
| Unwrapped 134 | 134 °C | 4 min | 12 min / extended 25 min |
| Unwrapped 121 | 121 °C | 20 min | 10 min / extended 20 min |
| Wrapped 134 | 134 °C | 4 min | 15 min / extended 25 min |
| Wrapped 121 | 121 °C | 20 min | 15 min / extended 20 min |
| Custom | 121 / 134 °C | 4–60 min | 5–60 min |
| BD-HELIX test | 134 °C | 3.5 min | 4 min |
| Leak test | −82 kPa vacuum | 15 min test hold | Not applicable |
Color Screen programs
Swipe the table sideways to view all columns. The first column stays visible.
| Program | Temperature | Hold time | Drying time |
|---|---|---|---|
| Universal 134 | 134 °C | 4 min | Selectable drying mode |
| Universal 121 | 121 °C | 20 min | Selectable drying mode |
| Fast 134 | 134 °C | 4 min | Selectable drying mode |
| Custom | 121 / 134 °C | 4–60 min | 5–60 min |
| BD-HELIX test | 134 °C | 3.5 min | 4 min |
| Leak test | −82 kPa vacuum | 15 min test hold | Not applicable |
Pro programs
| Program / function | Selection overview |
|---|---|
| Universal / Fast 134 | Universal and Fast 134 °C options are available. Request the cycle timings for your selected configuration and load. |
| Drying | Vacuum drying described; loading and program settings affect the result. |
APPLICATION-LED SELECTION
Application Scenarios
Plan 23G capacity, programs and cycle records around the instruments and daily workload of your facility.
Dental clinics
Match chamber depth, wrapping and cycle selection to reusable dental instrument sets and daily batches.
Ophthalmic clinics
Review delicate reusable instrument sets against their processing instructions and the selected sterilizer program.
Veterinary clinics
Plan reusable instrument processing around permitted loads, packaging and the available work area.
Laboratories
Confirm that reusable items and heat-resistant glassware are compatible with the selected steam cycle.
BEFORE YOU SPECIFY
Frequently Asked Questions
Are the three versions the same size?
The listed cabinet dimensions are 652 × 420 × 495 mm for Standard and Pro, and 660 × 455 × 445 mm for Color Screen. Compare the version columns and confirm the installation drawing for the ordered unit.
How should I compare Pro cycle times?
Request full-cycle data for your actual load, packaging and selected program. Sterilization hold time alone does not include heating, air removal, pressure release or drying, and cannot establish the total turnaround time.
How should I select the capacity?
Compare the actual instrument and tray dimensions, normal batch contents, wrapping requirements and available processing space. Nominal capacity alone does not establish the permitted load or usable tray arrangement.
Can the page replace the operating manual?
No. This page is for equipment comparison and project enquiries. Use the current manual and instrument instructions for operation, loading, cycle selection, safety checks and maintenance.
What documents should I request for my market?
Specify your country and the model/version being considered. Ask for the relevant configuration data sheet, installation drawing, operating manual and applicable regulatory documentation, including the scope covered.
What information helps RUNDA prepare a quotation?
Send your application, capacity, preferred version, daily workload, market, power and plug requirements, printing needs, expected quantity and any OEM requirements. The team can then review a defined configuration.
START THE RIGHT CONVERSATION
Are You an End User or a Distributor?
Choose the route that best describes your organization so RUNDA can focus the enquiry on application support or commercial cooperation.
LET’S DEFINE YOUR CONFIGURATION
Discuss 23G for Your Project
Share your application, required capacity, preferred version and target market. Include your instrument workflow, documentation and OEM requirements so we can review the right configuration together.
Ask About 23GBrowse all infection control products →