RUNDA · TABLETOP AUTOCLAVES
CLASS B23K Class B Vacuum Steam Sterilizer · 18L/23L
Defined versions for different operating requirements.
RUNDA manufactures the 23K tabletop vacuum steam sterilizer range for professional instrument-processing workflows. Compare Standard, Color Screen and Pro configurations, with 18 L / 23 L options and clearly separated chamber, loading and electrical specifications.
- 18 L / 23 L
- Three configuration choices
- Vacuum drying
Model: 23KBrand: RUNDA
PRODUCT INFORMATION
Technical Parameters
The 23K offers Class B vacuum processing with Standard, Color Screen and Pro choices. Chamber size, electrical protection and permitted loads are compared by version to support a precise equipment enquiry.
23K Performance Highlights
Class B vacuum processing
Pre-vacuum and vacuum drying support wrapped and unwrapped instrument cycles. Choose an 18 L or 23 L chamber to suit your tray sizes and daily workload, with permitted loads specified for each version.
Flexible controls and cycle records
Choose Standard, Color Screen or Pro controls for your workflow. Color Screen and Pro offer program customization and cycle-information access; specify the printer configuration and output language for your documentation needs.
Configuration & Specifications
| Parameter | Standard | Color Screen | Pro |
|---|---|---|---|
| Capacity options | 18 L / 23 L | ||
| Chamber diameter × depth | 18 L: Ø245 × 355 mm; 23 L: Ø245 × 465 mm | 18 L: 250 × 350 mm; 23 L: 250 × 450 mm | |
| External dimensions | 652 × 420 × 495 mm | 655 × 415 × 475 mm | |
| Power supply | 220 V AC / 50 Hz | ||
| Electrical protection | T15A fuse | C16A miniature circuit breaker | |
| Water storage tank | 3.5 L | ||
| Maximum load | 18 L / 23 L: unwrapped 5 kg; wrapped 2.5 kg | 18 L: Unwrapped 3.8 kg; wrapped 2 kg; 23 L: Unwrapped 5 kg; wrapped 2.5 kg | |
| Program temperatures | 121 °C / 134 °C | ||
| Operating environment | +5 to +40 °C; relative humidity ≤85% | ||
| Referenced platform | — | MAX-23K-III | |
| Drying settings | — | Fast / Standard / Accelerated | |
— indicates a specification not listed for that version. Request the configuration sheet before ordering.
Sterilization Programs
Hold time and drying time are separate cycle phases. Select the program for the intended load and the supplied configuration.
Standard programs
| Program / function | Selection overview |
|---|---|
| Unwrapped 134 / 121 | Temperature-specific programs for permitted unwrapped loads. |
| Wrapped 134 / 121 | Temperature-specific programs for permitted wrapped loads. |
| BD-HELIX / leak test | Applicable test functions following the manual and local validation procedure. |
| Custom | Adjustment within the manual-defined operating range. |
Color Screen / Pro programs
| Program / function | Selection overview |
|---|---|
| Universal 134 / Universal 121 | 121 °C and 134 °C programs; select the validated cycle for the instrument and packaging. |
| Fast 134 / Fast 121 | Fast-program options for permitted loads. Request the configuration-specific full-cycle timing. |
| Strengthen 134 | Additional 134 °C program; settings and permitted loads follow the supplied manual. |
| Customize | Parameter selection within the manual-defined range for qualified users. |
| BD-HELIX / leak test | Test functions for the applicable routine checks; not instrument-processing programs. |
APPLICATION-LED SELECTION
Application Scenarios
Plan 23K capacity, programs and cycle records around the instruments and daily workload of your facility.
Dental clinics
Match chamber depth, wrapping and cycle selection to reusable dental instrument sets and daily batches.
Ophthalmic clinics
Review delicate reusable instrument sets against their processing instructions and the selected sterilizer program.
Veterinary clinics
Plan reusable instrument processing around permitted loads, packaging and the available work area.
Laboratories
Confirm that reusable items and heat-resistant glassware are compatible with the selected steam cycle.
BEFORE YOU SPECIFY
Frequently Asked Questions
Which specifications differ between 23K versions?
Standard and MAX-23K-III Color Screen / Pro configurations differ in chamber dimensions, cabinet dimensions, electrical protection and 18 L load limits. The comparison table keeps those values in their own version columns and merges only identical specifications.
Is a printer included with every 23K?
Printing is configuration-dependent. The product photograph shows a fitted printer; specify physical printouts, print-history access and the required output language so the supplied hardware can be confirmed.
How should I select the capacity?
Compare the actual instrument and tray dimensions, normal batch contents, wrapping requirements and available processing space. Nominal capacity alone does not establish the permitted load or usable tray arrangement.
Can the page replace the operating manual?
No. This page is for equipment comparison and project enquiries. Use the current manual and instrument instructions for operation, loading, cycle selection, safety checks and maintenance.
What documents should I request for my market?
Specify your country and the model/version being considered. Ask for the relevant configuration data sheet, installation drawing, operating manual and applicable regulatory documentation, including the scope covered.
What information helps RUNDA prepare a quotation?
Send your application, capacity, preferred version, daily workload, market, power and plug requirements, printing needs, expected quantity and any OEM requirements. The team can then review a defined configuration.
START THE RIGHT CONVERSATION
Are You an End User or a Distributor?
Choose the route that best describes your organization so RUNDA can focus the enquiry on application support or commercial cooperation.
LET’S DEFINE YOUR CONFIGURATION
Discuss 23K for Your Project
Share your application, required capacity, preferred version and target market. Include your instrument workflow, documentation and OEM requirements so we can review the right configuration together.
Ask About 23KBrowse all infection control products →

