RUNDA · TABLETOP AUTOCLAVES
CLASS B9A Class B Steam Sterilizer · 18L/23L
Class B performance. Clear everyday operation.
MAX-9A combines Class B vacuum-assisted cycles, automatic process control and cycle-record printing in a practical tabletop format. Choose an 18 L or 23 L chamber and specify the Standard or optional Color Screen interface for the intended instrument-processing workflow.
- Class B
- 18 L / 23 L
- Standard / Color Screen (Optional)
Model: 9ABrand: RUNDA
PRODUCT INFORMATION
Technical Parameters
Designed for dependable daily instrument reprocessing, the MAX-9A brings together Class B vacuum performance, automatic cycle documentation and flexible 18 L / 23 L capacity options in one practical tabletop platform.
9A Performance Highlights
Configuration & Specifications
| Parameter | 18 L | 23 L |
|---|---|---|
| Interface options | Standard / Color Screen (Optional) | |
| Chamber diameter × depth | Ø245 × 355 mm | Ø245 × 465 mm |
| External dimensions (L × W × H) | 630 × 455 × 445 mm | 660 × 455 × 445 mm |
| Maximum unwrapped load | 5 kg | 5 kg |
| Maximum wrapped load | 2.5 kg | 2.5 kg |
| Power supply | 230 V AC / 50 Hz; 110 V AC / 60 Hz | |
| Electrical protection | C16 miniature circuit breaker | |
| Water storage tank | 3.5 L | |
| 121 °C operating pressure | 1.0-1.3 bar | |
| 134 °C operating pressure | 2.1-2.3 bar | |
Sterilization Programs
Swipe the table sideways to view all columns. The first column stays visible.
| Program | Temperature | Pressure | Hold time | Drying time | Pulsation number | Minimum vacuum pressure (kPa) |
|---|---|---|---|---|---|---|
| Unwrapped 121 | 121 °C | 110 kPa | 20 min | 10 min | 1 | -80 kPa |
| Unwrapped 134 | 134 °C | 210 kPa | 4 min | 10 min | 1 | -80 kPa |
| Wrapped 121 | 121 °C | 110 kPa | 20 min | 15 min | 3 | -80 kPa |
| Wrapped 134 | 134 °C | 210 kPa | 4 min | 15 min | 3 | -80 kPa |
| Strengthen | 134 °C | 210 kPa | 20 min | 10 min | 3 | -80 kPa |
| Cotton / textile | 121 °C | 110 kPa | 20 min | 20 min | 3 | -80 kPa |
| BD-HELIX test | 134 °C | 210 kPa | 3.5 min | 4 min | 3 | -80 kPa |
| Leakage test | Vacuum test | -80 kPa | 15 min hold | Not applicable | Not applicable | -80 kPa |
Working Conditions & Storage
| Item | Requirement |
|---|---|
| Before long-term storage or transport | Disconnect power and completely drain the storage and waste-water tanks |
| Ambient temperature | +5 to +40 °C |
| Relative humidity | ≤85% |
| Atmospheric pressure | 70-106 kPa |
Compliance & Documentation
| Review item | Requirement |
|---|---|
| Sterilization class | Class B configuration confirmed by RUNDA for the 9A range |
| Final operating manual | Applies to MAX-18L-II and MAX-23L-II |
| Electrical configurations | 230 V AC / 50 Hz and 110 V AC / 60 Hz are documented; confirm the ordered supply and plug |
| Documentation scope | Confirm destination-market declarations and the exact Standard or Color Screen configuration before ordering |
APPLICATION-LED SELECTION
Application Scenarios
Choose the 9A chamber, interface and cycle documentation around the facility’s instruments, daily batches and validated workflow.

Dental clinics
Plan capacity around reusable instruments, tray dimensions, wrapping and normal daily batches.
Ophthalmic clinics
Match delicate reusable instrument sets to the approved cycle, packaging and traceability procedure.
Veterinary clinics
Review treatment and surgical instruments against the permitted load, chamber depth and program.
Laboratories
Confirm that heat-resistant glassware and reusable items are compatible with the selected steam cycle.
BEFORE YOU SPECIFY
Frequently Asked Questions
How do the 18 L and 23 L models differ?
The 18 L model has a Ø245 × 355 mm chamber and a 630 × 455 × 445 mm cabinet (L × W × H). The 23 L model has a deeper Ø245 × 465 mm chamber and a 660 × 455 × 445 mm cabinet. Allow the installation clearances specified in the operating manual when planning the bench space.
Can I choose a Color Screen interface?
Yes. Standard and optional Color Screen interfaces are available for the 18 L and 23 L capacities. Include your preferred interface in the enquiry so RUNDA can confirm the supplied controls, cycle programs and printing configuration.
Which power configurations are listed?
The final operating manual lists 230 V AC / 50 Hz and 110 V AC / 60 Hz configurations. Specify the required supply and plug when ordering, and follow the nameplate of the supplied unit.
How should I select the capacity?
Compare the actual instrument and tray dimensions, normal batch contents, wrapping requirements and available processing space. Nominal capacity alone does not establish the permitted load or usable tray arrangement.
Can the page replace the operating manual?
No. This page is for equipment comparison and project enquiries. Use the current manual and instrument instructions for operation, loading, cycle selection, safety checks and maintenance.
What documents should I request for my market?
Specify your country and the model/version being considered. Ask for the relevant configuration data sheet, installation drawing, operating manual and applicable regulatory documentation, including the scope covered.
What information helps RUNDA prepare a quotation?
Send your application, capacity, preferred version, daily workload, market, power and plug requirements, printing needs, expected quantity and any OEM requirements. The team can then review a defined configuration.
START THE RIGHT CONVERSATION
Are You an End User or a Distributor?
Choose the route that best describes your organization so RUNDA can focus the enquiry on application support or commercial cooperation.
LET’S DEFINE YOUR CONFIGURATION
Discuss 9A for Your Project
Share your application, required capacity, preferred version and target market. Include your instrument workflow, documentation and OEM requirements so we can review the right configuration together.
Ask About 9ABrowse all infection control products →