RUNDA · TABLETOP AUTOCLAVES
CLASS B8A Class B Automatic Steam Sterilizer · 18L/23L
Automatic processing for daily instrument workflows.
RUNDA manufactures the 8A steam autoclave for dental clinics, veterinary practices and professional instrument-processing areas. The 18 L and 23 L configurations combine automatic program control, pulsed pre-vacuum and vacuum drying in a tabletop format.
- 18 L / 23 L
- Pulsed pre-vacuum
- Vacuum drying
Model: 8ABrand: RUNDA
PRODUCT INFORMATION
Technical Parameters
Automatic cycle control, pulsed pre-vacuum and vacuum drying bring a focused instrument-processing workflow to the 8A. Compare the 18 L and 23 L chamber depths for your normal tray loads.
8A Performance Highlights








Configuration & Specifications
| Parameter | 18 L | 23 L |
|---|---|---|
| Chamber diameter × depth | Ø245 × 350 mm | Ø245 × 465 mm |
| Power | 1500 W | 2000 W |
| Weight | 49 kg | 54 kg |
| External dimensions (L × W × H) | 660 × 455 × 445 mm | |
| Electrical options | 110 V / 240 V; 50 Hz / 60 Hz — specify the ordered configuration | |
| Water storage tank | 3.5 L | |
| Program temperatures | 121 °C / 134 °C | |
| Operating environment | +5 to +40 °C; relative humidity ≤85% | |
Sterilization Programs
Hold time and drying time are separate cycle phases. Select the program for the intended load and the supplied configuration.
Swipe the table sideways to view all columns. The first column stays visible.
| Program | Temperature | Hold time | Drying time |
|---|---|---|---|
| Unwrapped | 134 °C | 4 min | 10 min |
| Unwrapped | 121 °C | 20 min | 10 min |
| Wrapped | 134 °C | 5 min | 15 min |
| Wrapped | 121 °C | 20 min | 15 min |
| Cotton / textile | 121 °C | 20 min | 20 min |
| BD-HELIX test | 134 °C | 3.5 min | 4 min |
| Vacuum leak test | Vacuum test | 15 min test hold | Not applicable |
APPLICATION-LED SELECTION
Application Scenarios
Plan 8A capacity, programs and cycle records around the instruments and daily workload of your facility.
Dental clinics
Match chamber depth, wrapping and cycle selection to reusable dental instrument sets and daily batches.
Ophthalmic clinics
Review delicate reusable instrument sets against their processing instructions and the selected sterilizer program.
Veterinary clinics
Plan reusable instrument processing around permitted loads, packaging and the available work area.
Laboratories
Confirm that reusable items and heat-resistant glassware are compatible with the selected steam cycle.
BEFORE YOU SPECIFY
Frequently Asked Questions
How do the 18 L and 23 L models differ?
The 18 L model has a Ø245 × 350 mm chamber, 1500 W power rating and 49 kg weight. The 23 L model has a Ø245 × 465 mm chamber, 2000 W power rating and 54 kg weight. Both list a 660 × 455 × 445 mm cabinet; allow the installation clearances required for the supplied unit.
Which program timings are shown?
The table separates sterilization hold and drying times for wrapped, unwrapped and textile programs. They are not advertised as total cycle duration; preparation, heating and pressure-release phases also take time.
How should I select the capacity?
Compare the actual instrument and tray dimensions, normal batch contents, wrapping requirements and available processing space. Nominal capacity alone does not establish the permitted load or usable tray arrangement.
Can the page replace the operating manual?
No. This page is for equipment comparison and project enquiries. Use the current manual and instrument instructions for operation, loading, cycle selection, safety checks and maintenance.
What documents should I request for my market?
Specify your country and the model/version being considered. Ask for the relevant configuration data sheet, installation drawing, operating manual and applicable regulatory documentation, including the scope covered.
What information helps RUNDA prepare a quotation?
Send your application, capacity, preferred version, daily workload, market, power and plug requirements, printing needs, expected quantity and any OEM requirements. The team can then review a defined configuration.
START THE RIGHT CONVERSATION
Are You an End User or a Distributor?
Choose the route that best describes your organization so RUNDA can focus the enquiry on application support or commercial cooperation.
LET’S DEFINE YOUR CONFIGURATION
Discuss 8A for Your Project
Share your application, required capacity, preferred version and target market. Include your instrument workflow, documentation and OEM requirements so we can review the right configuration together.
Ask About 8ABrowse all infection control products →