RUNDA · TABLETOP AUTOCLAVES
CLASS B8X Class B Vacuum Steam Sterilizer · 18L/23L
A choice of interfaces. A clearly defined workflow.
RUNDA manufactures the 8X tabletop vacuum steam sterilizer for professional instrument reprocessing. Choose an 18 L or 23 L chamber and a regular or color-screen interface, with program-specific pre-vacuum and vacuum drying for the permitted load configuration.
- Class B
- 18 L / 23 L
- Regular / Color Screen
Model: 8XBrand: RUNDA
PRODUCT INFORMATION
Technical Parameters
Built for demanding instrument reprocessing, the MAX-8X combines Class B vacuum performance, intelligent cycle control and flexible 18 L / 23 L capacity options—helping dental, clinical and laboratory teams process a wider range of loads with confidence.
8X Performance Highlights
Configuration & Specifications
| Parameter | 18 L | 23 L |
|---|---|---|
| Interface options | Regular / Color Screen (Optional) | |
| Chamber diameter × depth | Ø205 × 350 mm | Ø205 × 450 mm |
| Weight | 50 kg | 52 kg |
| External dimensions (L × W × H) | 665 × 455 × 445 mm | |
| Water storage tank | 3.5 L | |
| Program temperatures | 121 °C / 134 °C | |
Sterilization Programs
Swipe the table sideways to view all columns. The first column stays visible.
| Program | Temperature | Hold time | Drying time |
|---|---|---|---|
| Unwrapped | 134 °C | 4 min | 10 min |
| Unwrapped | 121 °C | 20 min | 10 min |
| Wrapped | 134 °C | 5 min | 15 min |
| Wrapped | 121 °C | 20 min | 15 min |
| Cotton / textile | 121 °C | 20 min | 20 min |
| Steam-compatible plastic | 121 °C | 20 min | 15 min |
| BD-HELIX test | 134 °C | 3.5 min | 4 min |
| Vacuum leak test | Vacuum test | 15 min test hold | Not applicable |
Working Conditions & Storage
| Item | Requirement |
|---|---|
| Before long-term storage or transport | Disconnect the power and completely drain both the storage tank and waste-water tank |
| Ambient temperature | +5 to +40 °C |
| Relative humidity | ≤85% |
| Atmospheric pressure | 70–106 kPa |
Compliance & Standards
| Review item | Requirement |
|---|---|
| Pressure equipment | Directive 2014/68/EU |
| Small steam sterilizers | EN 13060 |
| Electromagnetic compatibility | EN 61326 and applicable EN 61000 series requirements |
| Electrical safety | EN 61010-1 and UL 61010-1 |
| Sterilizer electrical safety | EN 61010-2-040 and IEC 61010-2-040 |
| Documentation scope | Compliance documentation for the exact 8X configuration and destination market must be confirmed before ordering |
APPLICATION-LED SELECTION
Application Scenarios
Bring Class B vacuum performance to professional instrument-reprocessing workflows across clinical and laboratory settings.

Dental clinics
Support routine processing of permitted wrapped, unwrapped, solid and hollow reusable dental instruments.
Ophthalmic clinics
Match the chamber, cycle and documentation to delicate reusable instrument sets and the clinic’s validated workflow.
Operating rooms
Plan capacity and cycle selection around approved instrument sets, packaging requirements and traceability needs.
Laboratories
Review solid, hollow, porous and internally channelled items against the selected steam cycle and load instructions.
BEFORE YOU SPECIFY
Frequently Asked Questions
Does every 8X cycle use three vacuum pulses?
No. The supplied program table lists one pulse for unwrapped cycles and three for wrapped and textile cycles. Program-specific settings should be checked in the current manual for the selected unit.
Can I order a different display?
Regular and Color Screen versions are described separately in the supplied materials. State the desired interface, capacity, display language and printing requirements so the final configuration can be confirmed.
How should I select the capacity?
Compare the actual instrument and tray dimensions, normal batch contents, wrapping requirements and available processing space. Nominal capacity alone does not establish the permitted load or usable tray arrangement.
Can the page replace the operating manual?
No. This page is for equipment comparison and project enquiries. Use the current manual and instrument instructions for operation, loading, cycle selection, safety checks and maintenance.
What documents should I request for my market?
Specify your country and the model/version being considered. Ask for the relevant configuration data sheet, installation drawing, operating manual and applicable regulatory documentation, including the scope covered.
What information helps RUNDA prepare a quotation?
Send your application, capacity, preferred version, daily workload, market, power and plug requirements, printing needs, expected quantity and any OEM requirements. The team can then review a defined configuration.
START THE RIGHT CONVERSATION
Are You an End User or a Distributor?
Choose the route that best describes your organization so RUNDA can focus the enquiry on application support or commercial cooperation.
LET’S DEFINE YOUR CONFIGURATION
Discuss 8X for Your Project
Share your application, required capacity, preferred version and target market. Include your instrument workflow, documentation and OEM requirements so we can review the right configuration together.
Ask About 8XBrowse all infection control products →